Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Cureus ; 16(2): e54757, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38524047

RESUMO

Acute compartment syndrome (ACS) is a critical orthopedic and traumatology emergency arising from elevated pressure within a confined osteofascial compartment, leading to compromised blood circulation and tissue ischemia. This systematic review aims to comprehensively identify and analyze the most predictable risk factors associated with ACS development in patients with forearm fractures. Published articles on ACS were meticulously searched and evaluated on reputable medical databases such as PubMed. The keywords "risk factors associated with the ACS in patients who have sustained forearm fractures"were used to create the search syntax on various databases. Data were gathered on raw prevalence, population under study, and methodology. A total of 10 articles that met the search criteria were identified and included in this review with a total of more than 300,000 patients across the studies. Fracture-related ACS was the most common, followed by soft tissue damage among patients with forearm fractures. This review underscores fractures as primary ACS catalysts, along with the role of soft tissue trauma. Meticulous consideration of these risk factors can enhance clinical decision-making, early detection, and intervention, improving patient outcomes and care quality.

2.
Anaesthesia ; 76(5): 617-622, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33470422

RESUMO

Disposable N95 respirator masks are the current standard for healthcare worker respiratory protection in the COVID-19 pandemic. In addition to shortages, qualitative fit testing can have low sensitivity for detecting poor fit, leading to inconsistent protection. Multiple groups have developed alternative solutions such as modified snorkel masks to overcome these limitations, but validation of these solutions has been lacking. We sought to determine if N95s and snorkel masks with attached high-efficiency filters provide consistent protection levels in healthcare workers and if the addition of positive pressure via an inexpensive powered-air purifying respirator to the snorkel mask would provide enhanced protection. Fifty-one healthcare workers who were qualitatively fitted with N95 masks underwent quantitative mask fit testing according to a simulated workplace exercise protocol. N95, snorkel masks with high-efficiency filters and snorkel masks with powered-air purifying respirators were tested. Respiratory filtration ratios were collected for each step and averaged to obtain an overall workplace protocol fit factor. Failure was defined as either an individual filtration ratio or an overall fit factor below 100. N95s and snorkel masks with high-efficiency filters failed one or more testing steps in 59% and 20% of participants, respectively, and 24% and 12% failed overall fit factors, respectively. The snorkel masks with powered-air purifying respirators had zero individual or overall failures. N95 and snorkel masks with high-efficiency filter respirators were found to provide inconsistent respiratory protection in healthcare workers.


Assuntos
COVID-19/prevenção & controle , Análise Custo-Benefício/normas , Pessoal de Saúde/normas , Máscaras/normas , Respiradores N95/normas , Adulto , COVID-19/economia , Estudos de Coortes , Desenho de Equipamento/economia , Desenho de Equipamento/normas , Feminino , Pessoal de Saúde/economia , Humanos , Masculino , Máscaras/economia , Pessoa de Meia-Idade , Respiradores N95/economia , Exposição Ocupacional/economia , Exposição Ocupacional/prevenção & controle , Equipamento de Proteção Individual/economia , Equipamento de Proteção Individual/normas , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
J Cardiothorac Vasc Anesth ; 35(6): 1654-1662, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33431273

RESUMO

OBJECTIVE: Determine whether the intraoperative three-dimensional left ventricular outflow tract cross-sectional area may be inversely correlated with pressure gradients as a determinant of surgical success after septal myectomy in hypertrophic cardiomyopathy patients. DESIGN: Perioperative data were obtained by retrospective review. SETTING: Toronto General Hospital, University of Toronto, Toronto, Canada, a tertiary hospital. PARTICIPANTS: The study comprised 67 patients with hypertrophic obstructive cardiomyopathy. INTERVENTIONS: Transthoracic and intraoperative transesophageal echocardiographic assessment of pressure gradients. Transesophageal measurement of the three-dimensional left ventricular outflow tract cross-sectional area. MEASUREMENTS AND MAIN RESULTS: The smallest left ventricular outflow tract area increased on average 1.883 cm2 (98.3%) after septal myectomy. There was a significant correlation between the increase in the area and the transesophageal pressure gradients (r = -0.32; p = 0.01) after myectomy, but none with postoperative transthoracic gradients at rest (r = -0.10; p = 0.42). Postoperative transesophageal and transthoracic gradients were significantly correlated (r = 0.26; p = 0.04). The best risk factors to predict high residual gradients were preoperative transesophageal gradient >97 mmHg, postoperative transesophageal area <3.16 cm2, and moderate or more residual transesophageal mitral regurgitation (specificity 89%, 81%, and 78%, respectively). CONCLUSIONS: Three-dimensional left ventricular outflow tract area measurements with transesophageal echocardiography after myectomy correlated fairly well with postoperative transesophageal pressure gradients. Patients with residual transthoracic elevated gradients after surgery at follow-up had a smaller transesophageal area and higher transesophageal pressure gradients immediately after the procedure. However, transesophageal pressure gradients after myectomy correlated poorly with follow-up transthoracic gradients at rest.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Canadá , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia
4.
J Clin Monit Comput ; 32(4): 647-650, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29124561

RESUMO

As the clinical advantages of vapor anesthesia (VA) for sedation of patients in ICU become more apparent, the ergonomics, economy and safety issues need to be better addressed. Here we describe the use of a new commercial digital in-line anesthetic vaporizer that can be attached to the inspiratory limb of a ventilator. If used with a simple, and easily assembled secondary circuit and anesthetic reflector, the circuit remains remote from the patient, the VA consumption approaches a physical minimum, VA level is controlled and monitored, and the tidal volume size is not limited.


Assuntos
Anestesia por Inalação/instrumentação , Nebulizadores e Vaporizadores , Anestésicos Inalatórios/administração & dosagem , Desenho de Equipamento , Humanos , Unidades de Terapia Intensiva , Ventiladores Mecânicos
5.
Acta Anaesthesiol Scand ; 62(2): 177-185, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29068042

RESUMO

BACKGROUND: A volatile anaesthetic (VA) reflector can reduce VA consumption (VAC) at the cost of fine control of its delivery and CO2 accumulation. A digital in-line vaporizer and a second CO2 absorber circumvent both of these limitations. We hypothesized that the combination of a VA reflector with an in-line vaporizer would yield substantial VA conservation, independent of fresh gas flow (FGF) in a circle circuit, and provide fine control of inspired VA concentrations. METHOD: Prospective observational study on six Yorkshire pigs. A secondary anaesthetic circuit consisting of a Y-piece with 2 one-way valves, an in-line vaporizer and a CO2 absorber in the inspiratory limb was connected to the patient's side of the VA reflector. The other side was connected to the Y-piece of a circle anaesthetic circuit. In six pigs, an inspired concentration of sevoflurane of 2.5% was maintained by the in-line vaporizer. We measured VAC at FGF of 1, 4 and 10 l/min. RESULTS: With the secondary circuit, VAC was 55% less than with the circle system alone at FGF 1 l/min, and independent of FGF over the range of 1-10 l/min. Insertion of a CO2 absorber in the secondary circuit reduced Pet CO2 by 1.3-2.0 kpa (10-15 mmHg). CONCLUSION: A secondary circuit with reflector and in-line vaporizer provides highly efficient anaesthetic delivery, independent of FGF. A second CO2 absorber was necessary to scavenge the CO2 reflected by the anaesthetic reflector. This secondary circuit may turn any open circuit ventilator into an anaesthetic delivery unit.


Assuntos
Anestesia com Circuito Fechado/instrumentação , Anestesiologia/instrumentação , Anestésicos Inalatórios/análise , Nebulizadores e Vaporizadores , Anestesia por Inalação , Animais , Dióxido de Carbono/isolamento & purificação , Estudos Prospectivos , Sevoflurano/análise , Sus scrofa , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...